Parameter Settings of Sundez SDAW-EVI Heat Pump

Parameter setting of Sundez SDAW-EVI heat pump

7.2.4 Data Setting:
Touch the “Setting” key for 3 seconds, then checking mode comes.

ParameterExplanationRangeDefaultRemark
L1: Water Tank Temperature Deviation (0~15°C )0°C
L2:Compressor Restart Temperature Deviation (3~18°C)5°C
L3: Set Outlet Water Temperature(35~80°C)55°C
L4:Upper Limit of Water Tank Temperature(30~65°C)60°C
L5: Permitted Ambient Temperature for Electric Heating Operation(0~35°C)0°C0: No electric heater
L6: Return Water Temperature (Reserved)
L7: (Reserved)
L8: Compressor running current check (0~33Amp)00: No check
L9: Temperature Setting for High and Low Speed Fan (ambient temperature 10~45°C)
h1: Defrost cycle(20~99 minutes)35minutes
h2: Coil temperature to enter defrost(-15~0°C)-1°C
h3: Defrost time (5~20minutes)10minutes
h4: Coil temperature to exist defrost (1~40°C)26°C
 